Each module is 2 Channels. Also includes various connections and control panels see pictures This unit needs one pallet for each rack assembly for safe transport. Pallet Dimensions: 48x40x86 Weight: lbs Features: Plug-in modular digital dimming system. Up to 96 2. High and very high filter choke rise times. Hard firing SSR option to run transformer. Cold cathode and low wattage loads. Contactor module options to switch motors.
HMI ballasts and other non-dimmable equipment. Dual electronics processor option for full redundant tracking backup. GFCI modules for use with luminaires in wet locations. To bring selected dimmers to full if processor fails, and can be actuated manually or automatically eg. This item is freight only. Refer to freightquote. We Will palletize and wrap free of charge. Viewing of item is always welcome.
Item will be placed on a standard size pallet unless a larger size is required. We will be shipping from a residential location. No forklift or dock available. Item located in Las Vegas, This unit needs one pallet for each rack assembly. Payments are due within 2 days 48 hrs Please make payments within this time or contact us if there is an issue. Please review description an photos as to the condition of the it. Please click to see the Manual. So please be sure that you are certain you want to have this item and not planning to return it.
Pictures are the actual picture of the item you are buying. What you see what you get. Thank you all. Please see my other items. This unit has been tested to power on only. No further testing has been done as we do not have knowledge on how to test this unit. Please see pictures in detail. Please be sure to check our other items for sale.
Thank you. And Good Luck! Payment can be made by Paypal Thank you for looking and Happy Bidding! I'm not able to test but they came for a working system. If there are any problems I will work with you to make it right.
Thank you for looking and good luck bidding. Posted with eBay Mobile;1? The CD80 Pack is a lightweight portable performance dimming pack containing twelve and twenty-four 2. With normal. No accessories are included with this sale. Strand CD80 Dimmer Module - 6. I have for sale a set of 3 Strand Century CD80 6. Sold AS IS. No returns. ULS brand- 6 channel dimmer dmx- tested and fully working in near perfect condition watchers.
Stop watching and start buying before price increases next week- 6 channels 10amp per channel 4 u rack mountable comes with 63amp single phase input breakers for each channel 2 x 15amp socket outlets per channel Picture is of actual item we encourage people to call for information and advice or email we encourage people to call for information and advice or email listing includes VAT and full vat receipt provided postage includes 8 mile round trip to post office.
Strand CD racks can be found everywhere- and now you can have just what everyone needs to keep these ol' workhorses running- spare parts! This auction is for one module for a CD80 rack- a 6 Kw dimmer- yes.
That's right 6, watt dimmer module! You need to be sure your rack is configured to support this- but what a wonderful spare to have on hand.
Strand Tempus dimmer card for the 6 way red coloured dimmers. And permus racks! Fully tested and working, just plug and go- no tools required!
Fuse holders sockets etc, call for advice no emails please we encourage people to call for information and advice or email we encourage people to call for information and advice or email Listing includes Vat a;06d2.
This dimmer is an industry standard. CD80 dimmer modules are easily repaired as most of the parts are commonly available. Part The fans in this unit are made by Howard Industries Worldwire. And AMB 65C. The unit measures: length 20 in.
All circuit breakers provide positive trip indication. Fully digital processor with simple to use front panel setup with alpha numeric display. User selectable fade curves as well as minimum and maximum level selection. Dual DMX inputs with mode selection. Daisy chain output passes combined levels on to next pack. DMX input patching.
Toroidal chokes for high-quality filtering. Full range of output connectors: stage pin. Twistlocks, u ground and multi-pin socapex. Payment Policy: I accept Paypal only. Payment is requested at the time of purchase. I try to ship within one 1 day of receiving an approved payment. Refund Policy: I cheerfully accept requests for refunds if they are received within 14 days of your receipt of the product.
Pulled from a working install. Tested and verified fully functional. Full specifications can be found at the manufacturer website. Strand Lighting SD-6 Dimmer. Comes with 3 phase plug.
Product Features-6 X13 Amp 2. We've got three old strand installation dimmers, 20 chans per dimmer, that seem to need ribbon cable to be connected to the demux. How much do you think it would cost to upgrade, because fuses are getting hard to find. The entire rig was installed by amateurs about 30 years ago. I've been told that the dimmers run at 20 Kw each. Our control room is situated about metres away, and houses the dodgy strand desk and the demux These sockets then connect up to the dimmers via 3 lengths of ribbon cable.
Should we upgrade the dimmers. Also, we have had lights flickering on and off with no signal being sent from eiher the desk or the demux. We have a very similar setup in our theatre and recently encountered a problem with one of our dimmer racks. I decided to remove the "dodgy old Strand desk" that we had installed - it's probably the same as yours and called a Duet.
I discovered that when I got rid of the old Strand desk, one of our dimmer racks no longer worked. Even though the dimmers are controlled by DMX via an ARRI demux, it seemed that the old ribbon cables you describe have to be connected, in order for some of the channels to work.
It might be worth checking whether all the ribbon cables are correctly and firmly connected - that might explain why some of your dimmers don't work. Flickering channels are usually due to a faulty triac in the dimmer.
I also have this problem with 5 channels on one of my dimmers. We have just decided not to use them in the meantime, until we can get the dimmers serviced. I would say your best bet would be to have your dimmers checked over by a qualified electrician, who might be able to fix the flickering channels and the unresponsive channels all in one go.
How long ago were they last serviced? First off, you don't have twenty channels per dimmer - what you call a "dimmer" is actually a box that contains a large number of dimmers in this case, Each dimmer therefore runs at 1kw. I don't understand if it's a fairly new console how it can be well past warranty. It sounds like you're a student at your school - I suggest you consult with someone with the authority to send the board off for repair if needed and that's a big if. You're only going to be able to contact Strand directly during business hours.
I suggest you, or someone else, contacts first the supplier you bought the desk from, and then Strand themselves. You don't know whether it's the board that's broken although obviously the licence issue needs resolving - you should test everything. I also find it hard to believe that a three phase dimming system was installed by "amateurs", and given that's what you are yourself, you probably shouldn't be so derisive about it How often do you blow fuses?
Because if you're getting through them, I'd say that's the problem. The fuses shouldn't be hard to find, they're fairly standard despite the age of the equipment. You can request the manual for the STM to download from here , that might be helpful. My bad saying "Dodgy old strand desk" I meant the series, but we used to have a GSX 48chan which I liked a lot, and was opposed to replacing. Damn good training desk. What do you think I should replace them with? Whilst the old STM dimmer racks are indeed old, there are pretty much bullet proof - two things however are common faults with them.
Either the thyristors blow due to age, or sometimes a full short across the outputs or the capacitors blow. I am a little bemused with the arrangement you describe for delivering the analogue feed to the racks. If I read right, your demux is by the control desk, which feeds printer cables odd in itself! Move the demux to a suitable location BY the racks and connect the analogue outputs from the 8 output sockets on that demux directly to the rack's analogue terminals - use some decent cable - stranded, preferably, though quality isn't a huge issue, as it's only got to carry 10v each leg.
I assume that you already have the necessary plugs as this must be how the control lines getto the printer cables, yes? All you need then is a single run of twin screened DMX cable the quality of which IS important to connect the desk to the demux.
And voila, you have an infinitely better setup for the control path. Now, you say out of the 3 racks, only 48 channels work Can anyone point me in the right direction in regards to getting the dimmer fixed?
I don't want to go down any DIY route. Any help would be greatly appreciated! We're not really in the position to purchase new dimming this year! Talk to WhiteLight - their service department can repair LD90 processors and suchlike - I think they do a part exchange service for processors too they used to certainly and it's a fairly east swapover to do.
A quick Google should find a phone number and please mention that Ian from CTS gave them a name check here :. I had a similar issue with my EC90's recently but luckily know someone who is trained to service them.
Turned out that the main incoming fuses for each rack, 3 per rack, had the first fuse for the first rack also being the fuse for the main processor. It will be a NH00 gL 10 amp fuse.
0コメント